• 1 – 20 t/h
  • 0.7 – 2 Mpa
  • Industrial
  • In Stock
  • Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.
  • Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.

WSN series gas / oil fired industrial horizontal steam boiler is a kind of safety and high efficiency heating equipment with fully automatic intelligent control system. It’s a boiler shell type 3 passes wetback oil/gas fired boiler. Usually, the WNS series steam boilers widely used for industry production and processing, such as textile mill, medicine industry, food & beverage industry, chemical industry, garment industry, food processing industry, and wood processing industry, moreover, it could be used for central heating in enterprise, hotel, hospital, civil architecture, etc.

Flue Temperature - an overview ScienceDirect Topi

Dan P. Manka, in Analytical Methods for Coal and Coal Products, Volume III, 1979. D Results. The plot of the analytical results in Fig. 3 are those for coking dry coal for 14 hr at a flue temperature of 2300°F. Concentration of hydrogen approaches a maximum of over 70 %, and the methane approaches the minimum of less than 1 % near the end of the coking cycle.

INSTALLATION INSTRUCTIO

2017-3-8 · or greater than that of the floor,wall or roof assemblies through which it passes. Duravent models DIS and DIS chimney may penetrate a combustible floor,wall or roof using the appropriate parts and openings sizes. See section D "Roof & Wall Penetration" for more details. Where, according to local code, no chase enclosure is necessary, models

LOGIC FLUE & ACCESSORIES GUIDE. - Ideal Boile

2017-7-26 · LOGIC FLUE & ACCESSORIES GUIDE. LOGIC COMBI C LOGIC COMBI ESP1 LOGIC+ COMBI C The boiler must be installed in a vertical position in accordance to the installation instructions. FLUE KITS top of the boiler and obtain air supply within the roof space, the secondary flue continuing to the external flue terminal. Offset applications

Boiler Flue Through conservatory roof DIYnot Foru

2016-3-29 · Our gas boiler flue on the kitchen wall needs to be extended on the outside to go up through a planned conservatory roof. Gas-Safe Eng tells me the parts are available and can be done fairly straightforward, by working in sync with the conservatory installer.

New boiler - length of flue and installation cos

2006-9-25 · I paid about £750 for the boiler iirc. Although the gas connection to the boiler is 15mm, you will need a thicker pipe going up to the boiler in order to maintain enough pressure at the inlet. I paid £300 for installation only, but that was very straight forward hand on wall and flue straight through, plus gas from meter about 1m away.

HIGH EFFICIENCY POSITIVE PRESSURE VENTING SYSTEMS

2018-8-5 · fire rating of the floor, wall or roof assemblies through which it passes. 3. Venting systems may penetrate a combustible roof or wall using the Ventilated Roof Flashing assembly or the Wall Firestop assembly. These are the only parts intended for use with combus-tible construction. All other parts, such as the Anchor Plate and Wall Support

ModelRated steam capacity(t/h)Rated working pressure(Mpa)Rated steam temperature(℃)Maximum transport size(m)
(L×W×H)
WNS1-0.7-Y(Q)10.71703.3×1.8×2.1
WNS1-1.0-Y(Q)111843.3×1.8×2.1
WNS1.5-1.0-Y(Q) 1.511843.0×1.8×2.0
WNS1.5-1.25-Y(Q)1.51.251943.0×1.8×2.0
WNS2-1.0-Y(Q) 211844.4×2.1×2.5
WNS2-1.25-Y(Q)21.251944.4×2.1×2.5
WNS3-1.0-Y(Q)311844.6×2.3×2.6
WNS3-1.25-Y(Q)31.251944.6×2.3×2.6
WNS4-1.25-Y(Q)41.251944.7×2.5×2.9
WNS4-1.6-Y(Q)41.62044.7×2.5×2.9
WNS5-1.25-Y(Q)51.251945.3×2.7×3.3
WNS5-1.6-Y(Q)51.62045.3×2.7×3.3
WNS6-1.25-Y(Q)61.251945.9×2.6×3.0
WNS6-1.6-Y(Q)61.62045.9×2.6×3.0
WNS8-1.25-Y(Q)81.251945.9×2.8×3.1
WNS8-1.6-Y(Q)81.62045.9×2.8×3.1
WNS10-1.25-Y(Q)101.251947.7×2.8×3.1
WNS10-1.6-Y(Q)101.62047.7×2.8×3.1
WNS15-1.25-Y(Q)151.251947.0×3.1×3.6
WNS15-1.6-Y(Q)151.62047.0×3.1×3.6
WNS20-1.25-Y(Q)201.251948.3×3.4×4.0
WNS20-1.6-Y(Q)201.62048.3×3.4×4.0