• 1 – 20 t/h
  • 0.7 – 2 Mpa
  • Industrial
  • In Stock
  • Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.
  • Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.

WSN series gas / oil fired industrial horizontal steam boiler is a kind of safety and high efficiency heating equipment with fully automatic intelligent control system. It’s a boiler shell type 3 passes wetback oil/gas fired boiler. Usually, the WNS series steam boilers widely used for industry production and processing, such as textile mill, medicine industry, food & beverage industry, chemical industry, garment industry, food processing industry, and wood processing industry, moreover, it could be used for central heating in enterprise, hotel, hospital, civil architecture, etc.

la fórmula de ahorro de energía en la caldera – caldera vapo

2017-9-7 · calderas para la industria Caldera industrial … rumus penghematan energi pada caldera. Caldera ZG tiene más de 70 años en la fabricación de calderas y recipientes a presión. Y nuestros productos incluyen caldera de cadena de rejilla …

Cara Menghitung Efisiensi Boiler Artikel Teknologi Indones

2015-11-4 · Efisiensi boiler adalah sebuah besaran yang menunjukkan hubungan antara supply energi masuk ke dalam boiler dengan energi keluaran yang dihasilkan oleh boiler. Namun demikian, efisiensi pada boiler dapat didefinisikan ke dalam tiga cara yaitu:

Jenis-Jenis Pembangkit Listrik, Pembahasan Lengka

Dengan pemanfaatan air sebagai energi primer, terjadi penghematan penggunaan bahan bakar. #2. PLTU (Pembangkit Listrik Tenaga Uap) Uap yang terjadi dari hasil pemanasan boiler/ketel uap pada Pusat Listrik Tenaga Uap (PLTU) digunakan untuk memutar

perhitungan kapasitas boiler water tu

rumus perhitungan steam boiler Industrial Autoclave 2017-4-3·rumus perhitungan kapasitas produksi ketel uap (Mu) Power Boiler Steam yang dihasilkan boiler ini menggunakan tipe water tube boiler. rumus penghematan energi pada Chat Online

Analisa Pemakaian Economizer Terhadap Peningkata

Kehilangan panas merupakan salah satu faktor penting yang sangat perlu diperhatikan dalam pengoperasian boiler. Kehilangan panas yang terlalu besar yang terdapat pad Analisa Pemakaian Economizer Terhadap Peningkatan Efisiensi dan Penghematan Bahan

Tentang Boil

2020-2-23 · Pada boiler yang relatif kecil, dengan kapasitas 10 MW, kehilangan radiasi dan yang tidak terhitung dapat mencapai 1 hingga 2 persen nilai kalor kotor bahan bakar, sementara pada boiler 500 MW nilainya 0,2 hingga 1 persen. Kehilangan dapat diasumsikan

(DOC) SISTEM OPERASI DAN ANALISIS MENAR

SISTEM OPERASI DAN ANALISIS MENARA PENDINGIN (COOLING TOWER) PLTP KAMOJANG

pengaruh korosi pada pipa boil

permasalahan yg sering terjadi pada cfb boiler CFBC Boil 2018-9-12·misalnya ion-ion kesadahan seperti Ca 2+ dan Mg 2+ dan akibat pengaruh gas penguapan. karena dapat menyebabkan korosi pada pipa-pipa boiler.

AUDIT ENERGI DAN ANALISIS PELUAN

Agus Rianto, 5350403063 (2007) AUDIT ENERGI DAN ANALISIS PELUANG PENGHEMATAN KONSUMSI ENERGI PADA SISTEM PENGKONDISIAN UDARA DI HOTEL SANTIKA PREMIERE SEMARANG. Under Graduates thesis, Universitas Negeri Semarang.

PERHITUNGAN EFISIENSI BOILER PADA INDUSTR

2009-7-15 · 58 Winanti.W,S dan T, Prayudi: 2006 J.Tek.Ling Edisi Khusus Hal. 58 - 65 Jakarta, Juli 2006 ISSN 1441 – 318X PERHITUNGAN EFISIENSI BOILER PADA INDUSTRI INDUSTRI TEPUNG TERIGU Widiatmini Sih Winanti dan Teguh Prayudi Peneliti di Pusat

la fórmula de ahorro de energía en la caldera – caldera vapo

2017-9-7 · calderas para la industria Caldera industrial … rumus penghematan energi pada caldera. Caldera ZG tiene más de 70 años en la fabricación de calderas y recipientes a presión. Y nuestros productos incluyen caldera de cadena de rejilla …

ModelRated steam capacity(t/h)Rated working pressure(Mpa)Rated steam temperature(℃)Maximum transport size(m)
(L×W×H)
WNS1-0.7-Y(Q)10.71703.3×1.8×2.1
WNS1-1.0-Y(Q)111843.3×1.8×2.1
WNS1.5-1.0-Y(Q) 1.511843.0×1.8×2.0
WNS1.5-1.25-Y(Q)1.51.251943.0×1.8×2.0
WNS2-1.0-Y(Q) 211844.4×2.1×2.5
WNS2-1.25-Y(Q)21.251944.4×2.1×2.5
WNS3-1.0-Y(Q)311844.6×2.3×2.6
WNS3-1.25-Y(Q)31.251944.6×2.3×2.6
WNS4-1.25-Y(Q)41.251944.7×2.5×2.9
WNS4-1.6-Y(Q)41.62044.7×2.5×2.9
WNS5-1.25-Y(Q)51.251945.3×2.7×3.3
WNS5-1.6-Y(Q)51.62045.3×2.7×3.3
WNS6-1.25-Y(Q)61.251945.9×2.6×3.0
WNS6-1.6-Y(Q)61.62045.9×2.6×3.0
WNS8-1.25-Y(Q)81.251945.9×2.8×3.1
WNS8-1.6-Y(Q)81.62045.9×2.8×3.1
WNS10-1.25-Y(Q)101.251947.7×2.8×3.1
WNS10-1.6-Y(Q)101.62047.7×2.8×3.1
WNS15-1.25-Y(Q)151.251947.0×3.1×3.6
WNS15-1.6-Y(Q)151.62047.0×3.1×3.6
WNS20-1.25-Y(Q)201.251948.3×3.4×4.0