• 1 – 20 t/h
  • 0.7 – 2 Mpa
  • Industrial
  • In Stock
  • Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.
  • Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.

WSN series gas / oil fired industrial horizontal steam boiler is a kind of safety and high efficiency heating equipment with fully automatic intelligent control system. It’s a boiler shell type 3 passes wetback oil/gas fired boiler. Usually, the WNS series steam boilers widely used for industry production and processing, such as textile mill, medicine industry, food & beverage industry, chemical industry, garment industry, food processing industry, and wood processing industry, moreover, it could be used for central heating in enterprise, hotel, hospital, civil architecture, etc.

Pipe & fittings Standards - Sunny Ste

This Standard covers overall dimensions, tolerances, ratings, testing, and markings for wrought factory-made buttwelding fittings in sizes NPS 1 ⁄ 2 through 48 (DN 15 through 1200). Fittings may be made to special dimensions, sizes, shapes, and tolerances by agreement between the manufacturer and the …

PRESSURE RELIEF VALVE ENGINEERING HANDBO

2018-2-20 · quality management system approved to the International Standard Organization s ISO 9000 quality standard requirements. With proper sizing and selection, the user can thus be assured that Emerson s products are of the highest quality and technical standards in the world of pressure relief technology. PRESSURE RELIEF VALVE ENGINEERING HANDBOOK

2 million Btu/h gas boiler – CFBC Boiler Manufactur

2017-9-20 · Condensing Boilers TriangleTube. Up to 2 million BTU/h with the Efficiency and Reliability of the Prestige … its output during lower demands to minimize boiler . A. Complete standard gas train assembly Btu/h Btu/hr Btu/hr % % 1,000,000 Heating surface Ft2 149.0 Boiler Shell Dimensions – Width

NATURAL GAS SPECS SHEET - NAE

2019-9-30 · NATURAL GAS SPECS SHEET Fuel Providers and their large volume Customers (particularly Electric Utilities and possibly other End Users) are used to defining fuel requirements in the form of Spec Sheets.

HYDROGEN PRESSURE SWING ADSORBER (PSA)

2017-8-22 · Gas Association (CGA) as CGA H-13, Hydrogen Pressure Swing Adsorber (PSA) Mechanical Integrity Requirements. This publication is intended as an international harmonized standard for the worldwide use and application of all members of the Asia Industrial Gases Association (AIGA), Compressed Gas Association, European Industrial

THERMOTECH WATERTUBE SIMONS BOILER CO. STEAM

2009-7-17 · standard, with the boiler pressure vessel undergoing shell, providing the boiler is operated and maintained within relevant standards, including water treatment. baffl e or combustion gas pathways. A feature of the boiler design is the identifi cation of the downcomers, which

PRESSURE RELIEF VALVE ENGINEERING HANDBO

2018-2-20 · quality management system approved to the International Standard Organization s ISO 9000 quality standard requirements. With proper sizing and selection, the user can thus be assured that Emerson s products are of the highest quality and technical standards in the world of pressure relief technology. PRESSURE RELIEF VALVE ENGINEERING HANDBOOK

Shell Diameter - an overview ScienceDirect Topi

2011-10-1 · Single segmental baffles are standard and by far the most widely used. Flue gas at 600°C is being used to heat water in two stage process In case 2, the retrofit constraint was removed allowing for changes in the dimensions of the shell and refractory. The capital cost reduces significantly and the improvement from base-case design is 60%.

Pipe & fittings Standards - Sunny Ste

This Standard covers overall dimensions, tolerances, ratings, testing, and markings for wrought factory-made buttwelding fittings in sizes NPS 1 ⁄ 2 through 48 (DN 15 through 1200). Fittings may be made to special dimensions, sizes, shapes, and tolerances by agreement between the manufacturer and the …

P&ID and PFD Drawing Symbols and Legend list (PFS

P&ID and PFD Drawing used various Symbols and Legend. If you want to learn how to read P&ID and PFD, you must know the legend used in this drawings.

STANDARD EFFICIENCY RANGE of OIL BOILE

2019-1-30 · indicator lights as standard (Kitchen S only) " 2 year comprehensive warranty which extends to 5 years on the boiler shell Output Range (kW/hr) Kitchen 50/70 white case Kitchen 70/90 white case Kitchen 90/120 white case Kitchen 120/150 white case Kitchen 150/200 white case Kitchen 200/250 white case Kitchen 250/310 white case height width depth

ModelRated steam capacity(t/h)Rated working pressure(Mpa)Rated steam temperature(℃)Maximum transport size(m)
(L×W×H)
WNS1-0.7-Y(Q)10.71703.3×1.8×2.1
WNS1-1.0-Y(Q)111843.3×1.8×2.1
WNS1.5-1.0-Y(Q) 1.511843.0×1.8×2.0
WNS1.5-1.25-Y(Q)1.51.251943.0×1.8×2.0
WNS2-1.0-Y(Q) 211844.4×2.1×2.5
WNS2-1.25-Y(Q)21.251944.4×2.1×2.5
WNS3-1.0-Y(Q)311844.6×2.3×2.6
WNS3-1.25-Y(Q)31.251944.6×2.3×2.6
WNS4-1.25-Y(Q)41.251944.7×2.5×2.9
WNS4-1.6-Y(Q)41.62044.7×2.5×2.9
WNS5-1.25-Y(Q)51.251945.3×2.7×3.3
WNS5-1.6-Y(Q)51.62045.3×2.7×3.3
WNS6-1.25-Y(Q)61.251945.9×2.6×3.0
WNS6-1.6-Y(Q)61.62045.9×2.6×3.0
WNS8-1.25-Y(Q)81.251945.9×2.8×3.1
WNS8-1.6-Y(Q)81.62045.9×2.8×3.1
WNS10-1.25-Y(Q)101.251947.7×2.8×3.1
WNS10-1.6-Y(Q)101.62047.7×2.8×3.1
WNS15-1.25-Y(Q)151.251947.0×3.1×3.6
WNS15-1.6-Y(Q)151.62047.0×3.1×3.6
WNS20-1.25-Y(Q)201.251948.3×3.4×4.0
WNS20-1.6-Y(Q)201.62048.3×3.4×4.0